Ver6 Rev16

All past revisions

Release NotesUPDATE:2024/7/25

Rev16 of Ver6 has been released. The main changes are as follows.
  • Added the Gantt Chart control.


Additional Features

  • FA-Panel, FA-Server

    Added support for Mitsubishi Electric iQ-R/iQ-L Ethernet (binary protocol and ASCII protocol). This raises the upper limit of the addresses that can be communicated with.
  • FA-Panel, FA-Server

    Added support for the Mitsubishi Electric CC-Link IE Field Network controller board.
  • FA-Panel, FA-Server

    Added the GetSourceProperty common method.
  • FA-Panel

    Added an argument to the UpdateTitle route method.
  • FA-Panel, FA-Server

    Added the ReverseStr route method.
  • FA-Panel

    Added the OnBeforeSortFilter event to the Grid control.
  • FA-Panel

    Added the GetDialogProperty / SetDialogProperty form control methods.
  • FA-Panel

    Added minWidth / minHeight to the systemParam argument of the OpenDialog / OpenModalDialog common methods (syntax 1).
  • FA-Panel

    Added the autoScroll argument and others to the SelectMenu / SelectId methods of the Side Menu control, so that the menu scrolls automatically when the method is executed as the default behaviour. The autoOpen / autoScroll arguments have also been added to the ScrollMenu method of the Side Menu control.
  • FA-Panel

    Added the ScrollId method to the Side Menu control.
  • FA-Panel

    Added the ToggleOpenType property to the Side Menu control.
  • FA-Panel

    Added the OnOpenPopup event to the Side Menu control.
  • FA-Panel

    Added the SortCompareNoCase property to the column/row properties of the Grid control.
  • FA-Panel

    Added the volumeName argument to the GetDriveType route method.
  • FA-Panel

    Added the NumberFormat property to the column/row properties of the Grid control.
  • FA-Panel

    Added the Temp property to the column/row properties of the Grid control.
  • FA-Panel

    Added MERGEDDATA to the HDSRequestType property of the Historical Data control.
  • FA-Panel, FA-Server

    Added the 10th argument (bNullIsEmptyString) to the SaveCsvFile route method.
  • FA-Panel

    Added the GetAllDialogName route method.
  • FA-Panel, FA-Server

    Added ADDINGTIME2 to the aggregation method (SummaryType) of the Summary action.
  • FA-Panel, FA-Server

    Extended the MODICON driver so that, when -1 is specified for the maximum read size or maximum write size of each device under "Other detailed settings" - "Maximum communication size", packets are not optimised and communication is performed per tag.
    Example) If 100 tags are defined, a total of 100 communications are performed on each folder update cycle.
  • FA-Panel, FA-Server

    Improved the speed of the Summary (ODBC) action, which took a long time to go online when SQLServer was used and a large number of tag fields (for example, tens of thousands) were defined.
  • FA-Panel

    Added the Gantt Chart control.


Fixed point

  • FA-Panel, FA-Server

    Fixed an issue in the Logger (ODBC) action and the Historical Data Server (ODBC) where processing took a long time to start when SQLServer was used and the number of fields in a table exceeded several hundred.
  • FA-Panel, FA-Server

    Fixed an issue in the Historical Data Server action where duplicate field names could be set.
  • FA-Panel, FA-Server

    Fixed an issue in the Summary action where, when aggregation was time-shifted with ReportOffset / SummaryOffset, a higher-level aggregation (for example, the yearly report aggregation when the daily report is offset by 8 hours) could be performed even though the offset time had not been reached, if the server was brought back online some time after being taken offline.
  • FA-Panel, FA-Server

    Fixed an issue in Panel Server where an abnormal termination could occur when "Switch between main and sub unit" was selected from the menu displayed by right-clicking a communication driver unit.
  • FA-Panel, FA-Server

    Fixed the Summary (CSV) action so that the processing that retrieves RAW data from a client using the Historical Data Server function and the logging processing are no longer mutually exclusive. This reduces how often gaps occur in the data log while a trend graph is displayed.
  • FA-Panel

    Fixed an issue where an application error could occur the next time the system went online if a comment column [CMx] was added to the alarm master after the Alarm action had already been put into operation.
  • FA-Panel

    Fixed an issue in Panel Editor where an abnormal termination occurred when an object was selected after searching for the target browser file with the script search, with multiple browser files (xml) assigned to a single project and a non-existent theme defined in the VisualTheme route property of the browser file.
  • FA-Panel, FA-Server

    Fixed an issue where the actual value could not be retrieved even though "device" was specified for the third argument of the ReadVal common method from Panel Browser, when the tag value update had stopped - for example because "Update at the specified cycle" was unchecked in the folder or tag system properties.
  • FA-Panel

    Fixed an issue where drawing was incorrect when the Width / Height form properties were changed while a form was displayed in the View control.
  • FA-Panel, FA-Server

    Fixed an issue in Panel Server where the previous settings remained after selecting "New" or "Open" from the "File" menu, once the "Basic settings", "System settings" and "Browsing information" tabs of the properties shown under "Application" in the tree had been displayed.
  • FA-Panel

    Fixed an issue in the Demand action where no value was output to the predicted value output tag while the alarm was paused.
  • FA-Panel

    Fixed an issue where the scroll bar position was not adjusted when the form size was changed dynamically while a scroll bar was displayed in the View control.
  • FA-Panel

    Fixed an issue where the Capture method of the Video Player control returned F even though the JPEG file had been output successfully.
  • FA-Panel

    Fixed an issue in the Grid control where, with CELLS/COLS/ROWS selected for the SelectArea property and BORDER or BOTH specified for SelectType, only the border of the last selected area was drawn when multiple areas were selected.
  • FA-Panel, FA-Server

    Fixed an issue where unnecessary read communication occurred when multiple tags with non-contiguous but nearby addresses were set, in the case where the maximum read size of each device had been changed under "Other detailed settings" - "Maximum communication size" of the MODICON driver.
  • FA-Panel, FA-Server

    Fixed an issue where an application error occurred when a tag value was made negative, with the table type set to index in the tag filter "Convert to a number or string by referring to a table file".
  • FA-Panel

    Fixed an issue where the browser did not close when the X button at the top right was pressed while the preview screen was displayed after selecting "Print preview" from the Panel Browser menu.
  • FA-Panel

    Fixed an issue in the Summary (ODBC) action of Panel Server where printing or creating sub-reports consecutively could fail.



Download


   32Bit 64bit
Installer Download(Rev16) Download(Rev16)
Patches (execution environment) Download(Rev16) Download(Rev16)
Development resources (manuals, libraries, etc.) Download(Rev16)


FA-Server 32Bit 64bit
Installer Download(Rev16) Download(Rev16)
Patches (execution environment) Download(Rev16) Download(Rev16)
Development resources (manuals, libraries, etc.) Download(Rev16)
FA-Engine 32Bit 64bit
Installer Download(Rev16) Download(Rev16)
Patches (execution environment) Download(Rev16) Download(Rev16)
Development resources (manuals, libraries, etc.) Download(Rev16)